Magpuls
Magpuls

MAGPULS GmbH: UPS 3-phase/3-phase

FLEXUS FT

10 - 20kVA

FEATURES

  • Output power factor 0,9
  • Input current distortion <3%
  • Input power factor 0.99
  • AC/AC Efficiency up to 96.5 % in on-line operation, certified by TÜV
  • Battery management
  • Power walk-in
  • Multi-module configuration up to 6 modules
  • Multiple operating modes
  • Frequency converter mode
  • High overload capability (PF 0.8: 115% unlimited, 125 % for 10”, 150% for 1’, 168% for 5”)
  • IGBT- based rectifier assembly

APPLICATIONS

Local Area Networks, Servers, Data centers, cash registers, Telecommunication devices, e-Business, Industrial PLCS, Electromedical devices, Emergency devices.

FLEXUS FTH

10 - 40kVA

FEATURES

  • Output power factor 0,9
  • Input current distortion <3%
  • Input power factor 0.99
  • AC/AC Efficiency up to 96.5 % in on-line operation, certified by TÜV
  • Battery management
  • Power walk-in
  • Multi-module configuration up to 6 modules
  • Multiple operating modes
  • Frequency converter mode
  • High overload capability (PF 0.8: 115% unlimited, 125 % for 10”, 150% for 1’, 168% for 5”)
  • IGBT- based rectifier assembly

APPLICATIONS

Local Area Networks, Servers, Data centers, cash registers, Telecommunication devices, e-Business, Industrial PLCS, Electromedical devices, Emergency devices.

SENTRY MULTISTANDARD

60 - 80kVA

FEATURES

  • PFC circuit: PF up to 0,99
  • Input Harmonic distortion: THDi <4% with active filter
  • Battery management
  • Output PF from 0,8 leading to 0,8 lagging without derating of Active Power (kW)
  • High inverter short-circuit current capability (3 times nominal current)
  • Back feed protection
  • Multi-module parallel configuration up to 8 modules
  • Frequency converter 50/60Hz operation through operator panel
  • High overload capability (kVA): 110% (5h), 125% (10min), 150% (1min)
  • Additional Internal battery charger for long back-up time
  • Static and manual maintenance by-pass
  • Operating flexibility (four operating modes)
  • Communication: Watch&Save 3000 monitoring and Shutdown Software, SNMP, Jbus/Modbus, Profibus

APPLICATIONS

Servers, Local Area Networks (LAN), data centers, industrial PLCs, cash registers, emergency devices (lights/alarms), electro-medical equipment.

SENTRY HPS HT

10 - 80kVA

FEATURES

  • Total microprocessor control
  • Battery management
  • Low power consumption
  • High overload capability (kVA): 110% (5h), 125% (10min), 150% (1min)
  • Back feed protection
  • Multi-module parallel configuration up to 8 modules
  • Frequency converter 50/60Hz
  • High level diagnostics
  • EPO input for UPS shut-down using remote emergency front access
  • Minimum impact on the mains supply

APPLICATIONS

Servers, Local Area Networks (LAN), data centers, industrial PLCs, cash registers, emergency devices (lights/alarms), electro-medical and industrial equipment.

FLEXUS FT

100 - 120kVA

FEATURES

  • Output power factor 0,9
  • Input current distortion <3%
  • Input power factor 0.99
  • AC/AC Efficiency up to 94% in on-line operation, certified by TÜV
  • Battery management
  • Power walk-in
  • Multi-module configuration up to 6 modules
  • Multiple operating modes
  • Frequency converter mode
  • High overload capability (PF 0.8: 115% unlimited, 125 % for 10”, 150% for 1’, 168% for 5”)
  • IGBT- based rectifier assembly

APPLICATIONS

Local Area Networks, Servers, Data centers, cash registers, Telecommunication devices, e-Business, Industrial PLCS, Electromedical devices, Emergency devices.

SENTRY MPS-HP

100 - 400kVA

FEATURES

  • Efficiency up to 94% in on-line mode
  • IGBT-based rectifier assembly
  • High input power factor: 0.99
  • Low Input current distortion: <2.5%
  • Low Output voltage distortion with non linear load (EN 50091-3): < 3 %
  • High battery management level
  • Operation flexibility (On-line, Stand-by ON, Eco Mode, Smart Active)
  • Various system configurations: single module, multi-module up to 8 units, Dual bus system, Dynamic Dual bus system
  • High battery current recharge for long battery back-up times
  • Programmable remote alarms
  • Compact footprint: only 0.85 m2 for the 250kVA UPS model
  • Suitable for Genset sizing

APPLICATIONS

Servers, Local Area Networks (LAN), data centers, industrial PLCs, cash registers, emergency devices (lights/alarms), electro-medical and industrial equipment.

SENTRY MPS

100 - 800kVA

FEATURES

  • Low Output voltage distortion with non linear load (EN 50091-3): <3 %
  • High battery management level
  • Operation flexibility (On-line, Stand-by ON, Eco Mode, Smart Active)
  • Various system configurations: single module, multi-module up to 8 units, Dual bus system, Dynamic Dual bus system
  • High battery current recharge for long battery back-up times
  • Programmable remote alarms

APPLICATIONS

Servers, Local Area Networks (LAN), data centers, industrial PLCs, cash registers, emergency devices (lights/alarms), electro-medical and industrial equipment.

Back to top